Question 1
A 6-inch diameter vent measures 20 feet vertical; what is the maximum horizontal length of the 6-inch, single-wall connector?
Correct Answer:
15'
Explanation:
The key idea is how far a horizontal run of a single-wall vent connector can be while still maintaining adequate draft. For a 6-inch diameter vent, the common rule used in practice is that the horizontal length should not exceed about 75% of the vertical rise. With a vertical rise of 20 feet, 0.75 × 20 equals 15 feet. So the maximum horizontal length allowed is 15 feet. This keeps enough buoyant draft and helps prevent backdraft or condensation problems in the vent system. Shorter horizontals (like 10 or 12 feet) would still be acceptable, but they aren’t the maximum allowed. A 20-foot horizontal would exceed the recommended limit.
Question 2
A ______ is a strap with means for securing it about the waist and for attaching it to a lanyard, or deceleration device.
Correct Answer:
Body belt
Explanation:
A body belt is designed to be worn around the waist and to provide an attachment point for a lanyard or a deceleration device. This matches the description exactly: a strap that secures at the waist and has a way to connect the fall-arrest equipment. A safety harness, by contrast, is a full-body system with shoulder and leg straps that distribute fall-arrest forces across the body, not just at the waist. A waist strap alone is just a belt and may not provide the proper attachment points for a lanyard or deceleration device. A lanyard clip is just a hardware connector, not the belt itself.
Question 3
The products of which process are exhausted by an induced-draft blower in many HVAC systems?
Correct Answer:
Combustion
Explanation:
Induced-draft blowers are used to remove the gases produced when fuel is burned in the furnace or boiler. The combustion process creates hot, buoyant exhaust that must be vented outdoors to prevent buildup and to keep the system safe and efficient. By pulling these combustion byproducts through the vent stack, the blower carries out the products of combustion—primarily carbon dioxide and water vapor, along with any trace gases—out of the building. The other options aren’t what the blower is designed to exhaust: condensation is moisture that can form in some systems, ventilation refers to general air exchange, and evaporation is a phase change, not the specific exhaust function of the device.
Question 4
A single rooftop unit with 20,000 CFM supplies a three-story building. How many smoke detectors are needed?
Correct Answer:
3
Explanation:
Smoke detectors in HVAC systems are installed to quickly shut down the air handling unit when smoke is detected, preventing smoke from being spread through the building. When a single rooftop unit serves multiple floors, each floor ideally represents a separate zone that needs monitoring. This ensures that if smoke is detected on one floor, the system can respond appropriately for that zone without unnecessarily shutting down airflow to all floors. In this setup, there are three floors served by the unit, so one detector per floor is required, totaling three detectors. The unit’s size or airflow (20,000 CFM) doesn’t determine the number of detectors; it’s the number of separate zones or floors that matters.
Question 5
The cad cell on an oil burner detects what?
Correct Answer:
Flame
Explanation:
The cad cell is a flame detector. It works as a photoelectric sensor that responds to the light emitted by the flame. When a flame is present, the light lowers the cadmium sulfide cell’s resistance and sends a signal to the burner control to keep the fuel flowing. If the flame goes out, the signal changes and the control shuts off the fuel to prevent unburned oil. It’s not measuring pressure or noise, and it’s not reacting to general ambient light—it’s specifically detecting the flame’s light.
Question 1
Exam overview

About this Exam

Prepare with the HVAC D-2 license Practice Test practice quiz. This question bank includes 10 questions covering maximum, many, inch, burner, and square. Use it to review important concepts, identify knowledge gaps, and build confidence for the related exam, course, or assessment.

More details

Additional Information

HVAC D-2 license Practice Test

This practice set contains 10 questions from the matching question bank and focuses on maximum, many, inch, burner, and square. Work through each question carefully, review the provided solutions, and revisit topics that need more study before your next attempt.

This is an independent study resource intended for practice and review; it is not an official examination or an endorsement by any organization named in the title.

Quiz information

Frequently Asked Questions

The complete question count is available after full access is unlocked.
No fixed duration is currently configured for this quiz.
Question explanations are included where they are available in the quiz content, helping you review the reasoning after answering.
Yes. You can retake the practice test again as you continue studying during your available access period.
After your access is confirmed, you can continue into the complete practice exam from this quiz flow.
Unless explicitly stated otherwise, this page provides independent practice material for study and exam preparation and is not the official examination itself.
Keep studying

Related Questions